GR
GR Series Advanced Graphic Recorders
Specifications
43-TV-03-17, May 2015
Crystal Clear Display
• 5.7” High Resolution Digital Colour LCD (TFT)
• VGA Resolution (640 x 480 pixels)
• Clear and intuitive operation
• Industrial rugged Touch Screen with rapid navigation
• Custom Screens
Comprehensive Connectivity
• 10/100 Ethernet (DHCP), Web, Email
• FTP, TCP/IP and RS485 Modbus Protocol
• Modbus Master and Slave (option)
• USB ports for keyboard and mouse
Data Storage
• On-board non-volatile internal memory -
up to 4GB
• Removable Secure Digital (SD) card and USB storage
• No moving parts - all solid state Flash memory
Security Stringent - Total Data integrity
• Password Protection - 21CFR Part 11
• ESS - Extended Security System
• Password Network Synchronisation
Plus..
• Health Watch for preventative maintenance
• Remote Access - Advanced Software Data Analysis at
your PC and Remote Viewing
• Independent Chart and Logging speeds
• Global Language Support
• Rapid review and replay of data at recorder
• Approvals - CE, CSA, UL, FM & NEMA 4X / IP66
option
• Up to 50Hz (20 msec) Logging
• Up to 16 Analogue Inputs
• Reports - System generated
• Concurrent Batch mode
• AMS2750 Process Capabilities
Zobrazit stránku 0
1 2 3 4 5 6 ... 21 22

Shrnutí obsahu

Strany 1 - Specifications

Minitrend® GR GR Series Advanced Graphic Recorders Specifications 43-TV-03-17, May 2015 Crystal Clear Display • 5.7” High Resolution Digital Colo

Strany 2

Minitrend® GR 10 Minimum System requirements for TrendViewer:· Minimum System requirements for TrendServer Pro, TrendManager Pro and GR Series Scre

Strany 3 - Features

Minitrend® GR 11 Specification Design Attributes Digital indicators and Display Display size and Type: 5.7” diagonal, Digital Colour LCD (TFT) w

Strany 4

Minitrend® GR 12 Specification Design Attributes Common Relay Output (SPNC) NC common alarm relay: Two contacts, normally open when the recorder i

Strany 5

Minitrend® GR 13 Specification Design Attributes Cold Junction Compensation Internal compensation with the ability to manually adjust values, Exter

Strany 6

Minitrend® GR 14 Input Range Performance and Accuracy Input Actuation (Linear) Range Accuracy Temp. Stability +/- Input Impedance Millivolts DC -

Strany 7 - Firmware

Minitrend® GR 15 Input Actuation (T/Cs) Range Ref. Accuracy Temp. Stability +/- Field Cal Deg°F Field Cal Deg °C °F °C +/- °F +/- °C N*

Strany 8

Minitrend® GR 16 Specification Options Pulse Input (optional) 4 isolated inputs per board, frequency – 1Hz to 25kHz,

Strany 9 - Enhancements

Minitrend® GR 17 Connections

Strany 10

Minitrend® GR 18 Installation

Strany 11

Minitrend® GR 19 Model Selection Guides are subject to change and are inserted into the specifications as guidance only. Prior to specifying or ord

Strany 12

Minitrend® GR 2 Recorder Function • Honeywell’s Minitrend GR recorder provides flexible electronic data acquisition and recording in a high functio

Strany 13 - Specification Logging

Minitrend® GR 20 TVMIGRTABLE V - FIRMWARE CREDITS/OPTIONSAvailabilityStandard PasswordsESS (Permanent Password Capability)NoneFive CreditsTen Credit

Strany 14

Minitrend® GR 21 TVMIGRTABLE VIIAvailabilityFactory Use Only Grey Color Bezel, Standard Honeywell labeling 000Black Color Bezel, Standard Honeywell

Strany 15

For more information To learn more about HC 900 Process Controller, visit www.honeywellprocess.com Or contact your Honeywell Account Manager Proce

Strany 16 - Firmware Credit System

Minitrend® GR 3 Features Display • 5.7” High Resolution Colour Active TFT - with more than 256,000 colours makes it easy to interpret process dat

Strany 17

Minitrend® GR 4 Modbus Master/Slave The recorder can communicate with up to 32 slave devices on both RS485 and/or Ethernet at a maximum poll rate of

Strany 18

Minitrend® GR 5 Standard features • CE Mark - Conformity with 2006/95/EC, Low Voltage Directive and 2004/108/EC EMC Directive. • Common Relay Ou

Strany 19 - Minitrend Recorder

Minitrend® GR 6 Options – Hardware • Alarm Card - 4 or 8 outputs relay contacts SPCO 240V, 8 Digital I/O or 16 Digital I/O - SPNO 24VDC. Programmab

Strany 20 - GR 20

Minitrend® GR 7 Firmware Credit System The credits system is a flexible way of adding to the recorder features without having to upgrade the firmwa

Strany 21 - GR 21

Minitrend® GR 8 Firmware option Credit value Description Batch/Groups 5 The Batch function allows the user to segment portions of data for furth

Strany 22

Minitrend® GR 9 The TrendManager Pro Software Suite The TrendManager Pro Software Suite complements the capabilities of the “GR Series” recorders b